enIntegrated Motion

Evaluation Kit SOMANET Node SAFETY

Request Quote

About
Technology
Applications

This System Kit serves the evaluation of SOMANET Node Safety servo drives. It combines an assembled and industry-grade tested SOMANET Node Safety and all required accessories. This Kit allows you to test SOMANET with permanent magnet synchronous motors (PMSM/BLDC) of various sizes and integrate them as slaves in your EtherCAT system.

Please note this Kit is not for multi-axis setups or volume purchases. Refer to Product Page for SOMANET Node Safety to purchase quantities larger than 1.

SOMANET Node: Meet the most compact and flexible embedded EtherCAT Servo Drives.

  • Highly efficient model-predictive, field-oriented motor control software with advanced compensation of unwanted physical effects in drive (e.g. cogging)
  • EtherCAT or Ethernet communication (Profinet, SERCOS III, CAN, RS-485, WiFi and Bluetooth available on demand)
  • DS402 position, speed and torque/current control loops
  • High-res, high-speed ADCs for precise current and voltage measurements
  • Advanced protection circuitry
  • Control feedback through encoders and additional sensors via Hall, QEI/ABI/ABZ (RS-422), BiSS-C (RS-422), SSI, SPI, I2C and analog interfaces

Applications for the Evaluation Kit SOMANET Node include for example:

  • Traditional Robotic Arms
  • Collaborative Robotic Arms
  • Automated Guided Vehicles
  • Service Robots
  • Conveyor Belts
  • Special Machinery

Documentation Download CAD model

Clear
Order No.: SK-018-1-1 Category: Tags: ,
Description
Additional information

Safety Integration level (SIL) according to IEC 61508:2010 SIL 3
Performance Level (PL) according to ISO 13849-1:2015 PL e cat. 3
Safe Failure Fraction (SFF) 99.99 %
Probability of dangerous failure per hour (PFH_d) 1.07E-10 /hour
Probability of dangerous failure on demand (PFD_avg) 9.41E-6
Common Cause Failure (CCF) >65
Hardware Fault Tolerance (HFT) 1
Reaction time 10 ms
De-activation time 10 ms
Mean Time to dangerous Failure (MTTF_d) 3035 years (capped to 100 years)
Diagnostic coverage (DC_avg) 99%
HW-type Type A
Mission time T_M 20 a

SOMANET Node 400SOMANET Node 1000SOMANET Node 2000
Rated supply voltage12 - 48 / 60 V DC
Maximum input current DC9.6 A24 A48 A
Maximum Continuous Phase Current RMS13.2 A33 A36 A
Maximum phase current RMS13.2 A33 A66 A
Maximum Continuous Output Power415 W1,040 W1,200 W
Maximum peak power output415 W1,040 W2,080 W

Number of PMSM (BLDC) / brushed DC motors*1 / 2*
Brake power outputPWM controllable (0-48 V)
Efficiency at rated power98%
Position feedback sensor support (2 ports)Hall, QEI, BiSS-C, SSI, Half-Duplex, A-Format
Analog inputs (auxiliary)2 × single-ended 0-10 V, 2 × differential ±5 V (hardware-configurable upon request: 0-5 V, 0-10 V, 0-20 V, ±5 V, ±10 V)
Digital I/O4 × GPIO / SPI** / I²C** / UART
Notes* Currently not supported by our standard software. Can be developed upon request, please contact our Sales team for details.
** Upon Request

Please refer to our product documentation for more detailed specifications

Dimensions70 x 40 x 27.7 mm
Weight96 g (with Heatsink)

Compliance with standards:

  • CISPR 11 Class B (EN 55011:2016)
  • CISPR 11 Class B
  • IEC 61000-4-6:2013
  • IEC 61000-4-3:2020
  • IEC 61000-4-2:2008
  • IEC 61000-4-8:2009
  • IEC 61800-5-1:2007
  • IEC 60204-1:2016
  • IEC 61800-5-2:2017
  • ISO 13849-1:2015
  • IEC 61508:2010 parts 1-7

Compliance with European directives:

  • CE (EMC Directive 2014/30/EU)
  • CE (Machinery Directive 2006/42/EC)

Certificates:

  • TÜV Süd Mark (Functional Safety)
  • UL listed:
    Node 400, Node 1000 with soldered cables, Node 2000 with soldered cables
  • UL recognized:
    Node 1000, Node 2000
Weight 400 g
Dimensions 70 × 40 × 23 mm
Power rating

400, 1000, 2000